The STUF is the STBF throttle valve with a reverse flow check built into the same body. Oil is metered one way and runs free the other, so a ram goes out at the speed you set and comes back at full pump speed. Same steel body, same panel mount option, same seven port sizes.
Ways to buy this valve:
| Port Size | Max Flow | Max Working Pressure | Part Number |
|---|---|---|---|
| 1/4" BSPP | 15 L/min | 400 bar | STUF140 |
| 3/8" BSPP | 30 L/min | 400 bar | STUF380 |
| 1/2" BSPP | 50 L/min | 400 bar | STUF120 |
| 3/4" BSPP | 80 L/min | 400 bar | STUF340 |
| 1" BSPP | 150 L/min | 400 bar | STUF100 |
| 1-1/4" BSPP | 200 L/min | 350 bar | STUF114 |
| 1-1/2" BSPP | 300 L/min | 350 bar | STUF112 |
Check the pressure column. Everything to 1" is 400 bar. The 1-1/4" and 1-1/2" bodies are 350 bar.
| Parameter | Value |
|---|---|
| Brand | Oleoweb, made in Italy |
| Valve type | In-line throttle, metered one way, free flow the other |
| Port sizes | 1/4" to 1-1/2" BSPP parallel, female both ends |
| Max flow | 15 to 300 L/min depending on port size |
| Max working pressure | 400 bar to 1", 350 bar on 1-1/4" and 1-1/2" |
| Body material | Steel |
| Compensation | None, this is a fixed restriction |
| Panel mounting | Optional nut, four sizes, add it in the dropdown |
The check valve inside only bypasses the needle, it holds nothing. People fit one of these on a boom or a tipper and assume the free flow direction means the load is captured, and it is not, so use a pilot operated check or a counterbalance if the load has to stay put. Set the restriction with the machine warm and the load on, because a setting dialled in cold and unloaded will be well out once the oil is hot. Fit it as close to the actuator as the plumbing allows: a long run of hose between the valve and the ram acts like a spring and makes fine speed control mushy. If you are panel mounting, tighten the nut against the panel, never against the valve body, or the adjustment stem goes stiff.
STBF Throttle Valve, no check Flow Control, Reverse Free Flow Needle Valve, 1/4in to 1in VRFU Barrel Flow Control VCC Pressure Compensated
Need help choosing? Call 1300 146 737 or email sales@hydraulic.online, real technicians, real answers.