Industrial-Grade Efficiency for High-Pressure Systems The YEOSHE V-Series is a premier range of axial piston pumps designed for variable displacement applications where precision, energy saving, and thermal management are critical. These pumps feature a high-response swashplate design with a changeable angle, ensuring optimal performance across a wide variety of industrial and mobile applications. Engineered for low noise and high reliability, the V-Series is the professional choice for modern hydraulic power units.
Technical Specifications by Model:
| Model | Displacement (cm³/rev) | Max Flow @ 1500 RPM | Max Flow @ 1800 RPM | Max Pressure |
|---|---|---|---|---|
| V15 | 15.0 | 22.5 Lt/min | 27.0 Lt/min | 280 bar |
| V23 | 23.0 | 34.5 Lt/min | 41.4 Lt/min | 280 bar |
| V38 | 37.8 | 56.7 Lt/min | 68.0 Lt/min | 280 bar |
| V50 | 51.5 | 77.2 Lt/min | 92.7 Lt/min | 210 bar* |
| V70 | 69.7 | 104.5 Lt/min | 125.4 Lt/min | 210 bar* |
*V50/V70 Nominal Pressure is 175 bar; higher pressure adjustments available on request.
Standard Core Features:
V-Series Model Available Pressure Ranges, Mounting Flange, Oil Ports and Weight.
| Model # | Mounting Flange |
Displacement (cm³/rev) |
Press. Adj. Range (Bar) |
Max Speed (RPM) |
Min Speed (RPM) |
Inlet Thread |
Outlet Thread |
Weight (KG) |
| V15 | SAE A | 15 | 1: 8~70 / 2: 15~140 / 3: 20~210 / 4: 20~250 |
1800 | 500 | 3/4" BSPP | 3/4" BSPP | 13 |
| V23 | SAE B | 23 | 1: 8~70 / 2: 15~140 3: 20~210 / 4: 20~250 |
1800 | 500 | 1" BSPP | 3/4" BSPP | 22 |
| V38 | SAE B | 37.8 | 1: 8~70 / 2: 15~140 / 3: 20~210 / 4: 20~250 |
1800 | 500 | 1-1/4" BSPP | 1" BSPP | 26 |
| V50 | SAE C | 51.5 | 1: 8~70 / 2: 15~140 / 3: 20~210 | 1800 | 500 | 1-1/2" BSPP | 1-1/4" BSPP | 56 |
| V70 | SAE C | 69.7 | 1: 8~70 / 2: 15~140 / 3: 20~210 | 1800 | 500 | 1-1/2" BSPP | 1-1/4" BSPP | 56 |
"When selecting a pump from the V-Series, ensure your suction line is adequately sized to prevent cavitation;
These piston pumps are precision-machined and will not tolerate oil starvation.
For all models, the case drain must be connected directly to the reservoir and kept below 2 bar to protect the internal shaft seals.
On initial start-up, you must prime the pump by manually filling the case with clean, filtered hydraulic fluid via the top filling port.
Failure to do so will result in immediate catastrophic failure of the piston shoes and swashplate."