A certified-accuracy digital pressure gauge that reads in bar, psi, MPa and kg/cm² on a big backlit display, with peak-hold to catch the pressure spikes an analogue needle never shows you. Every gauge ships with its calibration certificate, instructions and battery, ready to work. Pick your range below and it is on its way.
Ways to buy this gauge:
| Range | Reads | SKU |
|---|---|---|
| 0-400 bar | 0-5,800 psi | SDI2.5-L-3-4-400 |
| 0-700 bar | 0-10,150 psi | SDI2.5-L-3-4-700 |
| 0-100 bar | 0-1,450 psi | SDI2.5-L-3-4-100 |
| Parameter | Value |
|---|---|
| Brand | SKON |
| Dial size | 63 mm (2.5") |
| Connection | 1/4" BSPP bottom entry (stem) |
| Accuracy | ±0.5% of full scale, certified |
| Display units | bar, psi, MPa, kg/cm² |
| Functions | Current reading, peak hold (max), backlight |
| Standard | EN 837-1/S2 safety requirements |
| Power | 9V battery (supplied) |
Use peak hold to find what is actually killing your hoses – set it, cycle the function hard over relief, and read the spike. It is routinely 20-30% over the gauge pressure you see steady-state, and that number is what your components are living with. Do not leave a digital gauge plumbed into a vibrating circuit permanently: connect through a test point and hose when you need a reading, then pull it off.
On hammer and fan-drive circuits that pulse, the hose itself damps the needle-snap that destroys gauges. And check the battery before a day of commissioning – a flat cell mid-test costs more time than it should.
In stock in Australia – express shipping available Australia-wide from our Gold Coast warehouse.
Need help choosing? Call 1300 146 737 or email sales@mhfgc.com.au – real technicians, real answers.