This is the tester the pros carry: the Webtec-built DHT digital hydraulic tester supplied through STAUFF Australia. Plumb it into the circuit and load the system with the built-in loading valve while reading flow, pressure and temperature on the one digital display – pump health, relief valve settings and drive efficiency, proven in minutes, no guesswork. Pick your flow capacity below.
Ways to buy your hydraulic tester:
| Flow capacity | Max pressure | Ports | Designation | STAUFF item no. |
|---|---|---|---|---|
| 300 L/min | 420 bar (6,000 psi) | 1" BSPP | WT-DHT03-L00300-B0420-G16 | 6100322710 |
| 400 L/min | 420 bar (6,000 psi) | 1" BSPP | WT-DHT04-L00400-B0420-G16 | 6100293793 |
| 400 L/min (Premium) | 420 bar (6,000 psi) | 1" BSPP | WT-DHT-L00400-B0420-G16 | 1810011396 |
| 800 L/min | 480 bar (7,000 psi) | 1-7/8" UNO | WT-DHT-L00800-B0480-U24 | 6100007744 |
| Parameter | Value |
|---|---|
| Brand / Origin | STAUFF-supplied Webtec DHT-series digital hydraulic testers (UK-built) |
| Type | Portable inline digital hydraulic tester: flow, pressure and temperature with built-in loading valve |
| Flow capacity | 300, 400 or 800 L/min models (bi-directional flow reading) |
| Maximum pressure | 420 bar (6,000 psi); 800 L/min model 480 bar (7,000 psi) |
| Readout | Digital display of flow, pressure and temperature; no external power needed |
| Connections | 1" BSPP female (300/400) or 1-7/8" UNO (800) |
| Safety | Internal burst disc protects the tester and circuit during over-pressure |
A digital tester with a loading valve is the only honest way to condition-test a pump: flow at idle pressure tells you almost nothing, because a worn pump can still push near-full flow with no load on it. Wind the loading valve up to working pressure and watch what the flow does – a healthy pump holds its flow within a few percent, a worn one falls away fast.
Do the same test at the same oil temperature every service and write the numbers down; the trend is worth more than any single reading. The built-in burst disc is your safety net, not a target – size the tester so your circuit's relief setting sits comfortably under the tester's rating, and always plumb the return to tank before you load up.
Flowtell SFF Sight Flow MetersSDM-750 Flow IndicatorsSDMKR Flow Indicator KitsTest Hoses (THA)
All Flow Meters & Pressure Test Kits
Need help choosing? Call 1300 146 737 or email sales@mhfgc.com.au – real technicians, real answers.