A modular check plate stops reverse flow through the P or the T port of a valve station.
Check on P stops one station back-feeding another when several functions share a manifold — without it, a heavily loaded function can push oil backwards into a lightly loaded one and make it creep.
Check on T holds a small back pressure in the return line. That keeps the line flooded and is often needed to give pilot operated valves elsewhere in the stack something to work against.
| Part number | Size | Port | Cracking pressure | Max flow | Bolt length |
| CV-02M-P-05 | Cetop 3 | P | 0.35 bar | 35 L/min | 40 mm |
| CV-02M-T-05 | Cetop 3 | T | 0.35 bar | 35 L/min | 40 mm |
| CV-03M-P-05 | Cetop 5 | P | 3.5 bar | 70 L/min | 55 mm |
| CV-03M-T-05 | Cetop 5 | T | 3.5 bar | 70 L/min | 55 mm |
Modular valves stack. Each plate you add makes the assembly taller, so the mounting bolts must be longer — the bolt length in the table is what that single plate adds. Add up your stack and order the matching SHCS bolt set; they are not included.